Abstract

This paper presents a method for determining a six-port reflectometer's response to a matched load with the use of partially known calibration loads. It utilizes nine calibration loads which can be of unknown magnitude and phase, however, three of them must exhibit magnitudes possibly close to each other with a reasonable phase separation. The algorithm was tested with the use of an exemplary broadband six-port reflectometer operating over the frequency range from 2.5 GHz to 3.5 GHz. The power values obtained using the proposed method are very close to those directly measured by the six-port reflectometer with a broadband matched load from precision calibration kit connected as DUT.