Abstract

In this research, two coated carbon electrodes were constructed and used for the determination of Trifluoperazine hydrochloride (TFPH) drug. The electrodes were constructed by preparing ion-pair for (TFPH) with phosphotungstic acid (PTA) or phosphomolybdic(PMA) acid using di butyl phthalate (DBP) as a plasticizer and poly vinyl chloride (PVC) as a matrix. These electrodes showed good sensitivity towards TFPH. Optimum temperature range (25 - 55 and 25 - 50)o C, limit of detection (4.99 ´ 10-6 and 4.56 ´ 10-6 ) M ,correlation coefficient, (0.9990 and 0.9980), slope (30.67 and 30.26) mV/decade for TFPH-PTA and for TFPH-PMA electrodes respectively.. Optimum pH range (2.7-6.6), the life time (48) days and linear range was (1´10-5 -1´10-2) M for both electrodes. These electrodes were successfully applied for determination of TFPH in pure and pharmaceutical preparations form.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.