Abstract

A specific, sensitive and precise method for the determination of tramadol in human serum is described. It comprises a three-step extraction procedure and a specific determination by capillary gas chromatography with nitrogen-selective detection, using a homologue of tramadol as an internal standard. The specificity of the method was checked by gas chromatography—mass spectrometry. Precision parameters were 1.7–5.5% (within-run) and 3.2–5.7% (between-run) in the concentration range 12.5–200 ng/ml. The detection limit was about 3 ng/ml.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.