Abstract

The sample is ashed in a nickel crucible over an open flame with calcium hydroxide as the fixative; fluoride is separated by micro-diffusion and measured with a fluoride-selective electrode. The calcium hydroxide fixative permits a temperature of 800–850°C during the final ashing, so that insoluble silicates are decomposed and fluoride is converted to an acid-soluble form. Other advantages over furnace ashing at 600°C are less contamination and more rapid ashing (20 min compared to 6 h). The interference of aluminium and silica on microdiffusion was studied: perchloric acid was found to be preferable to sulphuric acid as medium. A new way for preparing calcium hydroxide suspension, low in fluoride, is described. The values found by the proposed method generally compare well with those obtained by oxygen flask combustion. Direct diffusion (i.e. without ashing) gave much lower values than the ashing methods, except for tea leaves.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.