Abstract

A simple method has been developed to determine the concentration of organic chlorine in waste oil. The determination is based on the conversion of organic chlorine to inorganic chloride by reaction with sodium biphenyl followed by extraction with nitric acid and a mixture of nitric acid and water. The concentration of chloride is determined by direct potentiometry with an ion-selective electrode. The limit of determination amounts to 3·10−5 mol·l−1 chloride ions with a standard deviation of 3.5%. Different samples of waste oil have been analyzed and the results have been compared to those obtained by combustion in a H2/O2 flame followed by potentiometric titration with silver nitrate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.