Abstract

This paper presents a method to determine the minimum amount of a catalyst needed to operate a heterogeneously catalyzed reactive distillation column based on kinetic and VLE data only, avoiding rigorous column simulations. Good initial estimates for catalyst loadings are rarely discussed, and shortcut methods are lacking. The described method determines the highest possible reaction rate using known kinetics and column stage temperatures obtained from ternary diagrams of the column top and bottom sections, neglecting the highest or lowest boiler of the column, respectively. The method was validated against several literature cases. From these cases, it could be determined that a conservative estimate for the amount of the catalyst in the early design phase is six times the minimum catalyst found using the method described. Additionally, the presented method provides information regarding the operability of the column, for example, related to catalyst deactivation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.