Abstract

The response of neutron dosemeters may be determined directly from measurements, provided a sufficiently large number of measurements in monoenergetic neutron fields covering the entire energy range of interest is available. In practice this is not feasible due to the lack of monoenergetic neutron fields in the thermal and intermediate energy region (i.e. energies<24 keV). To deal with this difficulty, we have developed a method which can take into account additional information about the response of the dosemeter. Our analysis makes use of two types of data, measurements made using monoenergetic neutron beams and measurements made in neutron fields with broad energy distributions. The dosemeter responses are described using a parametrised model, based on a minimum of assumptions: that they should fit the data within experimental uncertainties, and that they should remain close to a simple interpolation of the monoenergetic and thermal neutron field data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.