Abstract

A new method has been developed for the determination of selected polybrominated diphenylethers (PBDEs) and polybrominated biphenyl (PBB) in four polymers: high-density polyethylene (HDPE), polystyrene (PS), acrylonitrile-butadiene-styrene copolymer (ABS), and polypropylene (PP). PBDEs and PBB in the polymers were extracted with toluene, using ultrasonic-assisted extraction (UAE). The extracts were then determined by high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS), using external calibration (single-point). Extraction parameters of UAE and several ICP-MS parameters were optimized. Extraction efficiencies almost reached 100%. The relative standard deviations (RSDs) were in the range of 0.7%-5.4%. The results demonstrate that the method possesses advantages of good precision, as well as high extraction efficiency and accuracy. The method especially overcomes the problem of the thermal degradation of highly brominated PBDEs, such as PBDE-209.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.