Abstract
An application that highlights the usefulness of a solid phase extraction sorbent having a removable surfactant "stationary phase" is introduced. Polyaromatic hydrocarbons (PAHs) efficiently trap on commercially available non-polar sorbents (i.e., C(18) silica). However, solvents that are necessary to break strong hydrophobic interactions between the analyte and sorbent are harmful and incompatible for direct introduction into a reversed phase liquid chromatographic setup. In the presented approach, the entire "stationary phase"-analyte association is removed, resulting in very efficient elutions with a final extract that is mild and reversed phase liquid chromatographic compatible. Commercial C(18) silica was placed adjacent to this sorbent to provide more efficient trapping of less hydrophobic PAHs. PAHs were preconcentrated from river water and were determined using fluorescence detection coupled to HPLC. Detection limits for all PAHs examined were in the sub [micro sign]g L(-1) level.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.