Abstract

An electron-capture GLC method was developed for measuring pindolol in human plasma and urine. The unchanged drug was extracted with benzene from alkalinized plasma or urine using propranolol as the internal standard. Both compounds subsequently were back-extracted into 0.1 M HCl and then into benzene. After evaporation of the organic phase, the compounds were derivatized with trifluoro-acetylimidazole to form the trifluoroacetyl ester of pindolol and propranolol. These derivatives then were analyzed by electron-capture GLC. The method allowed the measurement of concentrations as low as 1ng of pindolol/ml of plasma and was applied successfully to determinations of plasma levels in humans after oral administration of a single 10-mg dose of pindolol.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.