Abstract
The aim of this study is to determine the optimum heat insulation thickness for the glasswool and rockwool insulation material. Since natural gas is mostly used for heating in Turkey, it has been selected as fuel for the calculation. In order to calculate the optimum thickness of the insulation, the number of the degree-day and total environmental factor have been used. For the optimum insulation thickness, the decrease in exergy loss, CO2 emission and the fuel consumption were 75%, 73%, and 71% for the glasswool, respectively. On the other hand, for the rockwool, they were 35%, 18%, and 43%, respectively. Optimum thickness was calculated as 0.40 m for glasswool, and 0.18 for the rockwool.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.