Abstract
A potentiometric titration method and a conductometric titration method were standardized for the determination of nitrate in thorium, uranium and plutonium solutions in the range of 2–10 mg, and 15–30 mg, respectively, with a precision and accuracy of 2% in both cases. The results were compared with those of other methods like Devarda's alloy reduction method and volumetric titration method. The procedures standardized have been recommended for the determination of nitrate in heavy element solutions used for the preparation of oxide and mixed oxide microspheres by the sol-gel technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Radioanalytical and Nuclear Chemistry Articles
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.