Abstract

Nifedipine, a dihydropyridine calcium channel antagonist, is widely used in the treatment of hypertension and other cardiovascular disorders. A simple, rapid, sensitive, precise and accurate HPLC method, using solid-phase extraction, for the quantitation of nifedipine in human plasma was developed and validated. The calibration graphs were linear in the 5–400 ng/ml concentration range ( r>0.999). Recovery for nifedipine was greater than 93.9% and for internal standard nitrendipine was 96.1%. Intra-day and inter-day precision ranged from 1.4 to 4.2 and 3.9 to 5.6%, respectively. Intra-day and inter-day accuracy was ranged from 94.5 to 98.0 and 93.1 to 98.0%, respectively. The method was not interfered with by other plasma components and was applied for the determination of nifedipine in pharmacokinetic study after single oral administration of 10 mg nifedipine to 18 healthy male subjects.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.