Abstract
Mirtazapine is a new centrally acting noradrenergic and specific serotonin antidepressant, with an active demethyl metabolite. For toxicological purposes, a specific and accurate RP-HPLC assay was developed for the simultaneous plasma determination of these compounds. A linear response was observed over the concentration range 50–500 ng/ml. A good accuracy (bias <10%) was achieved for all quality controls, with intra-day and inter-day variation coefficients less than 8.3%. The lower limit of quantification was 20 ng/ml, without interferences with endogenous or exogenous components. This rapid method (run time <12 min) was used to manage three intoxications involving mirtazapine.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.