Abstract
A capillary electrophoresis method was described for the determination of metformin in human plasma based on the extraction of the ion-pair with bromothymol blue into chloroform. Phenformin was used as internal standard. Field-amplified sample stacking injection was employed with an electrokinetic injection voltage of 10 kV for 10 s. The running buffer was 0.1 M phosphate buffer (pH 2.5), running voltage was 20 kV and the UV absorbance detection was set at 195 nm. The limit of quantitation was 0.25 μg/ml. Linearity range of calibration curve was 0.25 to 3.5 μg/ml. Recoveries for three levels (0.25, 1 and 2 μg/ml) were 80.24%, 67.44% and 58.97% ( n=5 for each level), respectively. The intra-day precisions for the three levels were 11.9%, 3.09% and 4.33% and the inter-day precisions were 12.4%, 4.57% and 4.94%, respectively. The concentrations of metformin hydrochloride in human plasma of eight volunteers were measured after orally administrating metformin enteric-capsule and tablet.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.