Abstract

The lead content in fly-ash collected by an electrostatic precipitator has been determined by atomic-absorption spectrometry (AAS) after decomposition by four different leaching/dissolution techniques, and also determined by X-ray fluorescence spectrometry (XRFS) by the standard-addition method. The XRFS data were evaluated by non-linear regression since the standard additions affected the attenuation coefficient of the sample. Good agreement was obtained between the results obtained with AAS and XRFS. It is concluded that lead is quantitatively extracted by hot 1 M nitric acid or treatment with hydrofluoric acid/nitric acid. Direct measurement of briquetted samples by XRFS is suggested for rapid monitoring of the lead content in fly-ash from garbage incineration.