Abstract

An experimental investigation of a scaled-down model of an industrial exchanger, using an electrochemical technique, was undertaken in order to show the presence of hydrodynamic heterogeneities at low axial Reynolds number. Heterogeneities were revealed in the bowls with respect to the generalised Taylor number as the result of the perturbations added to the flow by blade rotation at both ends of the exchanger. Shear heterogeneities associated to flow visualisations were correlated to temperature heterogeneities observed in the bowls. Shear fluctuations were revealed in the scraped part describing two distinctive zones at low rotation speed caused by varying viscosity in the flow field. A complex spiral flow was observed by flow visualisation characterising a mass transfer evolution comprised between these two distinctive zones at low Taylor number.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.