Abstract

Hydroxylated radical products of salicylic acid are often used as a relative measurement in free radical research. Several analytical methods exist to determine the amount of 2,3-dihydroxybenzoic acid and 2,5-dihydroxybenzoic acid. In this study we use capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MECC) in order to determine these free radical products. The CZE experiment was optimized with a CZE simulation program hpcesim in order to achieve an optimal pH. Calibration curves were recorded in the range 10 −6–10 −4 M and the detection limit was determined. For both CZE and MECC it was 2·10 −7 M. Both methods resulted in a reproducible analysis of salicylate and its hydroxylated free radical products in 6 min.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.