Abstract

Sameridine is a new candidate drug with both local anaesthetic and analgesic properties. The free concentration of sameridine in blood plasma was determined by coupled-column liquid chromatography. Following adjustment of the pH and the temperature of the plasma samples, the free fraction was prepared by ultrafiltration. The coupled-column liquid chromatographic system consisted of a reversed-phase column, a cation-exchange extraction column and a cation-exchange analytical column. Sameridine was detected by UV determination at 205 nm and the system showed high selectivity. The limit of quantification was 1 n M and the within-day precision was 4.6% (R.S.D., n=10).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.