A rapid and simple method is presented for the determination of folic acid (FA) by capillary electrophoresis (CE) with chemiluminescence (CL) detection. This method was based on enhance effect of FA on the CL reaction between luminol and BrO − in alkaline aqueous solution. Optimal separation and determination was obtained with an electrophoretic buffer of 35 mM sodium borate (pH 9.4) containing 0.8 mM luminol, and an oxidizer solution of 1.6 mM NaBrO in 100 mM NaCO 3 buffer solution (pH 12.0). Under the optimal conditions, the determination of FA was achieved in less than 20 min, and the detection limit was 2.0 × 10 −8 M ( S/ N = 3). The relative standard deviations (RSDs) on peak area and migration time were in the 1.5 and 1.1%, respectively. The present CE–CL method was applied to the determination of FA in commercial pharmaceutical tablets, apple juices and human urine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.