Abstract

A simple analytical method for the quantitative determination of ethylenediaminetetraacetic acid (EDTA) in feed and premix formulations was developed and validated. The method involves an extraction with an acidic ferric chloride solution, to quantitatively convert EDTA species in the samples into the Fe(III)–EDTA complex, and its subsequent detection by Ion-Pair-Reversed Phase-High Performance Liquid Chromatography-Diode Array Detection (IP-RP-HPLC-DAD). A robust validation procedure was performed according to the Decision 2002/657/EC at concentrations ranging from 25 to 100mgkg−1 on sample. Good recoveries (85.6–92.8%) were obtained; repeatability of the method was in the range of 1.3–8.0%, with an intermediate precision ranging from 6.0% to 8.6%, both of them expressed as relative standard deviation (RSD). No interfering species hindered the straightforward detection of EDTA. Hence, the proposed method can be adopted for an effective and rapid routine analysis of products for livestock.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.