Abstract

The paper proposes a procedure of experimental data processing by the thin wall method for the diagnostics of stationary gas-flows. The procedure is based on solving an inverse convective heat transfer problem. It does not use smoothing and numerical differentiation of experimental data, and is resistant to measurement errors. Sensitivity coefficients are analyzed to find the most informative times for the determination of convective heat transfer parameters with the least influence of the measurement error. The numerical examples given show the effectiveness of the calculation procedure for the heat transfer coefficient and the gas-flow temperature determined from discrete measurements of the sensor temperature.