Abstract

A simple analysis method to detect clomazone residues in soybean and soil was developed using solid phase extraction coupled with high performance liquid chromatography with diode-array detection. The pesticide residues present in soybean and soil matrices were extracted with methanol-water and extracts purified with Florisil cartridges. The analytes from soybean and soil matrix were eluted with petroleum ether-acetic ether (10mL, 95:5, v/v) and petroleum ether-acetic ether (2mL, 95:5, v/v), respectively. The overall recovery of fortified soybean and soil at the levels of 0.01, 0.1 and 0.5mg/kg ranged from 89.75% to 106.6%, and the coefficients of variation (CV) ranged from 1.68% to 4.93% (n=3). The limit of quantification (LOQ) is 0.01mg/kg. This method has been applied to the analysis of clomazone in real samples of soybean and soil. The dissipation of residue over the time in soil coincided with C=1.189e(-0.0926t ) and the half-lives (T(1/2)) was 7.48days. The final residue in soybean was lower than 0.01mg/kg at harvest time. Direct confirmation of the analyte in real samples was achieved by gas chromatography-mass spectrometry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.