Abstract

A method for the determination of chlormequat chloride (CCC) residues in animal derived foods by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The samples were extracted with acetonitrile containing 1% (v/v) acetic acid and defatted with n-hexane, followed by clean-up on a cationic solid phase extraction column. The analytes were separated on a Venusil MP C18(2) column (150 mm×2.1 mm, 3 μm) under a gradient elution program using acetonitrile and 0.1% (v/v) formic acid aqueous solution as the mobile phases. Then, the analytes were detected by tandem mass spectrometry using a positive electrospray ionization (ESI+) source in the multiple reaction monitoring (MRM) mode. Matrix-matched internal standard calibration curves were used for quantitative analysis. The calibration curves showed good linearity in the range of 0.200-500 μg/L for CCC, with correlation coefficients (r2) no less than 0.9993. The limit of quantification (LOQ) of the method was 0.500 μg/kg. The average recoveries of CCC in pork, beef, mutton, chicken, egg, pig kidney, beef liver, sheep kidney, chicken liver and milk matrices at spiked levels of 0.500-500 μg/kg were 93.4%-101%, and the relative standard deviations were 2.3%-8.0%. The method has less matrix interference, with high sensitivity, accuracy and reliability, and it is suitable for the quantitative detection of CCC residues in animal derived foods.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call