Abstract

A simple and rapid liquid chromatographic method for the determination of atenolol in plasma is described. Plasma proteins were precipitated with zinc sulphate and sodium hydroxide prior to injection onto a precolumn, which was connected to the analytical column by a switching valve. When atenolol was eluted onto the analytical column, the precolumn was cleaned by backflushing to eliminate strongly retained endogenous compounds. The atenolol fluorescence was measured after excitation at 197 nm. The limit of quantitation in plasma was 15 ng/ml. The within-day precision of atenolol was 1.6% at a level of 210 ng/ml, 5.0% at 25 ng/ml and the between-day precision was 3.3% at 50 ng/ml.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.