Abstract

A simple, rapid, and sensitive method for determining 10 arylamine compounds in wastewater sample using solid-phase extraction (SPE) and high performance liquid chromatography (HPLC) with UV detection is developed. An SPE procedure is described for extracting and preconcentrating the arylamines on Sep-Pak C18 cartridges with methanol as solvent. A mobile phase gradient of acetonitrile-water was used for the separation and determination of the arylamines. The detection limits of the compounds were in the range of 0.1−1.5 μg/L. Recoveries were 84−107% for 10 arylamines at concentration levels of 20 μg/L with relative standard deviations of less than 8% (n = 4).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.