For experimental α determination the two-monitor method has been applied to determine α parameter in the irradiation channels at TRIGA 14 MW reactor (SCN Pitesti). The modified two-monitor method by using Cd ratio measurements eliminates the introducing of systematic errors due to the inaccuracy of absolute nuclear data. This characterization of the epithermal neutron spectrum is used in the k 0-method of NAA, implemented at the SCN Pitesti. Neutron spectrum parameters were determined in the inner irradiation channel XC-1 and for outer irradiation channels: Beryllium J-6, Beryllium J-7, and Beryllium K-11. For α and f parameter verification a standard reference material denominated ECRM379-1 was analyzed using k 0 standardization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.