Abstract

The first nuclear research reactor in Nigeria has been commissioned for neutron activation analysis and limited radioisotope production. In order to extend its utilization to include the k0-standardization method, the following neutron spectrum parameters in inner and outer irradiation channels were determined by the “Cd-ratio for multi-monitor method”: the thermal-to-epithermal flux ratio, f, and the epithermal flux shape factor, α. Neutron spectrum parameters determined in the inner irradiation channel B2, are: α = -0.052±0.002 and f = 19.2±0.5. For the outer irradiation channel B4, the neutron spectrum parameters were found to be α = +0.029±0.003 and f = 48.3±3.3. The results are compared with the neutron spectrum parameters of other reactor facilities with similar core configuration such as the Slowpoke and Miniature Neutron Source Reactor facilities available in the literature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.