Abstract
A method for acetate determination using IC separation and FI post-column spectrophotometric detection based on the La(OH)3-I2 reaction has been developed. The chromatographic conditions (eluants, flow-rates, sensitivity, and so on) and FI variables (length of coils, injection volume, pH, ... ) were optimized. Linearity was observed over the concentration range 0 to 1 gl-1 with HAc as standard (r = 0.9916) and a detection limit of 0.1 g AcH/l. The IC-FI method afforded a low relative standard deviation (3.6%) and was free from interferences. The IC-FI procedure was applied to the determination of acetate in mustard sauce and the results obtained agree with those provided by the reference method. Additionally, the developed method permits the simultaneous chromatographic analysis of other anions such as chloride, nitrate, phosphate, sulphate, and so on.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.