Abstract

7-[(2,2-Dimethyl)propyl)]-1-methylxanthine (I, Lab code MX2/120) is a new potent antibronchospastic agent. A rapid and simple HPLC assay for I in guinea pig plasma has been developed. Compound I was extracted from plasma with dichloromethane by a solid-phase extraction procedure, after adding 1,3-dimethyl-7-pentylxanthine at a concentration of 5 μg/ml as the internal standard (I.S.). The extraction residue was redissolved in water—acetonitrile and chromatographed on a RP-18 reversed-phase column. The eluate was monitored by spectrophotometric detection at 280 nm. The method showed good linearity over the range 0.1–20 μg/ml ( r = 0.9998) and is precise (C.V. × Student's t-test = 1.84%) and accurate (mean recovery ± limit of confidence = 100.25 ± 0.34). The HPLC assay was successfully applied to the determination of the pharmacokinetic profile of I after intravenous and oral administration in guinea pigs. The main pharmacokinetic parameters are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.