Abstract

In order to establish a rapid and sensitive method for the detection of Verotoxigenic Escherichia coli O157 and O26, a collaborative study was conducted focusing on a comparison of the efficiency of loop-mediated amplification (LAMP) assay targeting the Verocytotoxin (also called Shiga toxin) gene, utilizing a direct plating method and a plating method with immunomagnetic separation (IMS-plating method) using various agar media. In combination with enrichment with the modified EC supplemented with novobiocin, E. coli O157 was detected in most samples of ground beef and alfalfa sprouts by LAMP assay, the direct plating method and the IMS-plating method. E. coli O26 was detected in approximately 100% of the food samples by LAMP assay. However, the IMS-plating and direct plating methods recovered 80 and 50% in ground beef samples, respectively. As a result, it was demonstrated the LAMP assay is superior to the IMS-plating method. Based on these results, it appears LAMP assay is effective as a screening assay to detect E. coli O157 and O26 from positive samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.