Abstract
The applicability of a complement consumption assay as a means by which to detect IgG aggregates and immune complexes in serum was examined. Both heavy (greater than or equal to 19S) and intermediate (11-17S) IgG aggregates were detected and the sensitivity of the assay was greater than or equal to 10 mug aggregated IgG/ml. BSA anti-BSA complexes, formed in slight antibody excess, were detected at a BSA concentration of 200 ng/ml. NHS stored at 4degreesC for greater than or equal to 2-3 weeks or at -20degreesC for more than 3 months developed distinct anticomplementarity (AC). This background AC, due to IgG aggregate formation, was reduced by heating the serum at 56degreesC for 50 min prior to testing. A similar reduction of AC and C1q fixation was observed when IgG aggregated at 61degreesC or 63degreesC was heated further at 56degreesC for 50 min. The abatement of AC could not be correlated to a change in IgG aggregation size. In contrast, AC of preformed antigen-antibody complexes was not reduced by this heat treatment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Acta Pathologica Microbiologica Scandinavica Section C Immunology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.