Abstract

Analysis and comparison were carried out for evaporator stations having a 4th effect consisting either of two falling-film type vessels or two vessels of different designs – one Robert and one falling-film. The influence of the order, in which two apparatuses are installed in a serial layout in the 4th effect on the evaporation efficiency was analysed. A 4th effect consisting of 2 vessels was also compared to a 4th effect consisting of one vessel. The characteristics of 4th effect with one apparatus are used as a reference point for this analysis. Significant differences were found in the heat exchange efficiency of the analysed variants. It is worth carrying out an analysis when designing the modernization/extension of an evaporator station in order to obtain an optimal layout under specific conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.