Abstract

The volumetric flow rate of smoke generated from the fire in large space often reaches to hundreds of thousands CMH because of extended floor height and as it’s more difficult to isolate the smoke to the limited area, comparing to normal-scale building, design and operation of effective smoke control system for large space is more than important. In this study, with the analysis model for such a large space as exhibition hall or conference room in conventional center, design of mechanical smoke exhaust system was conducted based on currently-available design standard which was then followed by numerical analysis of the design using 3D numerical analysis method. For conference room at 2.0 MW heat release rate, 99,173 CMH flow rate is required, if smoke layer is maintained at 60% of the floor height and for exhibition hall at 8.8 MW with 80% of floor height, flow rate required is 219,802 CMH, which are incorporated into the design. In view of 3D numerical analysis, accuracy of the design according to algebraic expression is sufficient.

Highlights

  • Construction of the structure with large space began in earnest in 1980s in line with the construction of indoor stadium for the booming international indoor sports events in Korea, which has maintained a growing tendency along with increasing number of large and complex buildings

  • The volumetric flow rate of smoke generated from the fire in large space often reaches to hundreds of thousands CMH because of extended floor height and as it’s more difficult to isolate the smoke to the limited area, comparing to normal-scale building, design and operation of effective smoke control system for large space is more than important

  • With the analysis model for such a large space as exhibition hall or conference room in conventional center, design of mechanical smoke exhaust system was conducted based on currently-available design standard which was followed by numerical analysis of the design using 3D numerical analysis method

Read more

Summary

Introduction

Construction of the structure with large space began in earnest in 1980s in line with the construction of indoor stadium for the booming international indoor sports events in Korea, which has maintained a growing tendency along with increasing number of large and complex buildings. Ahn the smoke to the limited area, comparing to normal-scale building, design and operation of effective smoke control system for large space is more than important. Recognizing the hazards caused by fire smoke in large space in many countries, smoke control design guideline for large space has been developed and proposed worldwide since 1980s [1] [2] and the study to enhance the reliability of smoke control analysis technologies in large space through a full-scale test is still in process [3] [4] and recently, the measures to improve the smoke control system focusing on air supply and smoke exhaust efficiency is under review [5] [6] as well. Design of smoke safety system by mechanical smoke exhaust in conventional center was presented with the application of currently-available design standard followed by 3D numerical analysis method

Design Guideline for Mechanical Smoke Exhaust System in Large Space
A Full-Scale Large Space Building
Design of Mechanical Smoke Exhaust System in Large Space
Numerical Analysis of Mechanical Smoke Exhaust System in Large Space
Findings
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.