Abstract

AbstractIn calculating the resistance of welds within the connections between hollow sections in EN 1993-1-8, very general information is given without presenting specific calculations. The chief recommendations indicate that the resistance of the welds connecting the wall to the second element should not be less than the resistance of the cross section of the wall. In addition, assessment of the welds’ resistance based on the effective lengths is viable in cases when forces in the braces are smaller than the resistance of the joint, though the detailed method was not specified. The objective of this paper is to present the most up-to-date information about the design of overlap welded joints with a reinforcing rib plate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.