Abstract

The effective length and design of the perimeter weld around the branch member in axially-loaded Rectangular Hollow Section (RHS) T and X connections is examined experimentally. By means of 16 full-scale connection tests, which were designed to be weld-critical, guidelines for the effectiveness of the heel, toe and side welds are developed in terms of the principal connection parameters. It is found that more of the weld perimeter is effective for lower branch member to chord member angles, and more weld is effective for smaller width branch members (relative to the chord member size). The effective weld length recommendations advocated are highlighted to result in weld designs with an adequate level of safety using the current American Institute of Steel Construction specification, LRFD or CSA specifications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.