Abstract

Based on the principle of time difference method and the design concept of high precision, the measuring principle together with the improvement of the calculation method of the time difference method were investigated, aim at the problems of high complexity of the circuit and the inadequate precision of the traditional ultrasonic flowmeter that require pipeline modification. To promote the precision accuracy of the ultrasonic flowmeter to 0.5%, the function principle and its related structure of highprecision timing chip, TDC-GP22 (Time-to-Digital-Converter) were elaborated; and the design of hardware circuit and the working process of the system were introduced. The cause of signal attenuation was analyzed and the amplifying circuit for transmitting signal was designed. Finally, a flowmeter system design based on ATmega single chip and high-accuracy timing chip TDC-GP22 was proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.