Abstract
An intelligent control system to measure the developing height of water flowing fractured zone is proposed in this paper. The method of double end sealing water detection is adopted in this system. The hardware design principle, the software programming and the debugging process of the system are illustrated in detail. The control core part of this system is a 32-bit MCU STM32F107VCT6. The other parts consist of intelligent sensors, data collecting circuit, data transmit and storage circuit, electrical valve control circuit and human-machine interface circuit using touch screen. The purpose of this project design is to achieve the detection and analysis of the developing rules of the height of water flowing fractured zone by means of collecting, storage and analysis of the displacement signal, pressure signal, and flow signal in upward holes under the coal mine. This detection method is widely used in safe coal mining owing to its high performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.