Abstract

This paper describes a digital reactivity meter module based on solving the inverse kinetics equations and the time behavior of the output pulse frequency from the amplifier, which is proportional to the power of the Dalat Nuclear Research Reactor (DNRR). The designed reactivity meter, which operates online with real-time calculation, was tested using the PGT-17R simulator signals in comparison with the existing imported module PNO-121R5 of the DNRR’s control and protection system. The experimental results show that the technical characteristics and functions of the two modules are equivalent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.