Abstract

Presented are the main design features and performance results of the Cathode Strip Chambers for the CMS Endcap Muon system. Although the strips are unusually wide (up to 16 mm ) for the cathode-to-anode wire distance of 5 mm , the six-plane structure of these chambers yields a spatial resolution of about 80 μm , essentially uniform and independent of the strip width. In addition, the net spatial resolution of about one-tenth of the strip width at the hardware trigger level (300 ns ) is obtained using a simple network of comparators. Time resolution achieved at the trigger level is ∼4 ns (rms) that allows unambiguous tagging of bunch crossings which occur every 25 ns . Aging test results, including those obtained with a recirculating gas system, are discussed; only minor aging affects were observed. The aging studies were performed with large-scale chambers; 700 m of wire were irradiated for a dose up to 0.4 C / cm of the total accumulated charge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.