Abstract

In the wake of a series of outbreaks of finished pharmaceutical product-related Burkholderia cepacia complex (Bcc) human infections worldwide, the United States Food and Drug Administration (FDA) in 2017, and subsequently in 2021, issued advisory notifications to the pharmaceutical industry for stringent Bcc testing requirements for pharmaceutical manufacturing processes and for finished pharmaceutical products prior to release to the marketplace. The advisory notifications highlight non-sterile aqueous finished pharmaceutical products as being a major culprit associated with many of these human infection events. As such, there has been a significant number of Bcc-contaminated finished product recalls resulting in company revenue losses, delayed finished product release, finished product shortages for patients, and manufacturing plant shutdowns coupled with company reputational damage. With many of the finished product recall events, pharmaceutical grade water and/or manufacturing facility water distribution systems were identified as the primary origin source of Bcc contamination. Testing and monitoring regimes currently employed to identify Bcc contamination of water associated with pharmaceutical manufacturing are often limited by costly, laborious, lengthy, and nonspecific traditional microbial culture-based methodologies. Presently FDA approved, European Conformity (CE) marked, and International Organization for Standardization (ISO) standard microbial culture-independent rapid, quantitative, specific, and sensitive nucleic acid diagnostics (NAD) methodologies are now gaining greater widespread acceptance in their routine usage in testing laboratories. Here we present the development of a rapid (<4 hours from sample in to result out) single test culture-independent Bcc NAD method, incorporating a quantitative real-time polymerase chain reaction (qPCR) assay. This method can be used for the detection and simultaneous identification of all 24 Bcc species currently assigned, directly from water samples. This culture-independent Bcc NAD method is validated to the testing method equivalent of the ISO/TS 12869:2019 standard, which is a widely used rapid culture-independent NAD method for detecting Gram-negative Legionella species in water.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.