Abstract

This paper studies the relationship between the parameters in LLC resonant circuit based on the fundamental wave analysis method, analyzes the gain curve and the soft-switching conditions of the power tube, gives the selection method of the parameters k and Q and calculates the resonant component parameters. In this paper, a closed-loop frequency modulation control method is used to control the DC output voltage of the resonant converter. At the same time, mathematical modeling and analysis are carried out for the electrochemical model and thermal model of the proton exchange membrane (PEM) hydrogen production electrolyzer, and the Simulink simulation tool is used to complete the joint simulation of the PEM electrolysis model and the LLC resonant converter. The simulation results fully reflect the actual control process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.