Abstract

The cryostat chiefly consists of external vacuum housing, 60 K shield screens, liquid helium vessel with an SC multipole magnet inside, vacuum chamber (beam duct) with copper liner inside, and four two-stage cryocoolers with a stage temperature of 4.2 K/60 K. Current leads have heat in-leak interception in vacuum using cryocoolers. The helium vessel is suspended with four vertical and four horizontal CFRP (T300) tension rods connected to the external cryostat vessel. These tension rods pass throughout the 60 K shield screens and attach to bolts on the external housing walls and are used for precise alignment of the vertical magnet position.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.