Resonant-cavity parallel baffles, either empty or with a thin absorbent lining, have been investigated as an alternative to fiberglass-filled baffles commonly used to control noise emission from large ducts. A method for predicting silencer attenuation is described, and it is shown that the new type of baffle is characterized by an acoustic performance similar to that of fibrous baffles, while being virtually immune to such problems as clogging, erosion, or settling. The emphasis of the study is on insertion loss measurements in a 7 by 10 ft wind tunnel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.