Abstract

This work takes the production and usage scenarios of the data glove as the research object and studies the method of applying the flexible sensor to the data glove. Many studies are also devoted to exploring the transplantation of flexible sensors to data gloves. However, this type of research still lacks the display of specific application scenarios such as gesture recognition or hand rehabilitation training. A small amount of experimental data and theoretical analysis are difficult to promote the development of flexible sensors and flexible data gloves design schemes. Therefore, this study uses the self-made flexible sensor of the research group as the core sensing unit to produce a flexible data glove to monitor the bending changes of the knuckles and then use it for simple gesture recognition and rehabilitation training.

Highlights

  • Gesture recognition technology mainly refers to the user’s use of simple gestures to interact with the device

  • Design and Test of Flexible Sensor. e bending sensor of the data glove is the basic equipment for collecting data

  • For gloves with flexible sensors, experiments have found that the sensors have good repeatability and can be used to judge different finger movement states

Read more

Summary

Introduction

Gesture recognition technology mainly refers to the user’s use of simple gestures to interact with the device. Ey mainly compared bending and stretching sensors, IMU inertial sensors, and magnetic sensors. By analyzing the inherent characteristics and movement characteristics of a human finger, a flexible stretch sensor suitable for collecting finger bending can be designed. Rough training, the gesture recognition of the data glove using the flexible sensor was completed. For the collection of finger bending, commonly used sensors include inertial-based acceleration sensors and flexible stretch and bend sensors. Considering the comfort of wearing, we use the flexible sensor we designed, combined with the design of the circuit and the appearance of the glove, so as to complete the manufacture of our data glove. Is study mainly uses a flexible bending sensor coated with graphene, a new material, as a data acquisition sensor. We used a stretcher to stretch and use a multimeter to test the resistance change during the stretching process

Sensor stretcher multimeter
AGND VD
Results and Discussion
Sensor D Sensor E
Pinky finger to finger

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.