Abstract
Vibration can influence the imaging quality and tracking precision of the moving opto-electronic platform seriously, some measures of reducing vibration must be taken into consideration. In this paper the influence which vibration works on the imaging quality is analyzed, a novel design scheme of the damping mechanism is proposed, two new type Metal Rubber Isolators are designed, and two dimensional dynamic angle measuring instrument using linear CCD is applied to measure the dynamic rotational displacement of the opto-electronic platform. The result of vibration sweeping experiment shows that the isolator mechanism can reduce the three axis’ vibration higher than 25Hz. The angle-measurement result presents that the maximum rotational displacement is , which is suited to the demands of the imaging experiment.