Abstract

In this paper, ∞ux of permanent magnet tubular linear generator (PMTLG) is modeled and analyzed. With the model, air-gap leakage ∞ux coe-cient can be expressed analytically in terms of permanent magnet dimensions and air-gap width. The validity of analytical expression of air-gap leakage ∞ux coe-cient is verifled by flnite element analysis (FEA) with a maximum error of 6.8%. Furthermore, longitudinal end ∞ux's in∞uence on the detent force of PMTLG is analyzed in detail with the model. A detent force minimization technique is deduced from the analysis results, and conflrmed by FEA. Finally, after optimization of air-gap leakage ∞ux coe-cient and detent force, a PMTLG is built and experimented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.