Abstract

Abstract It is necessary to find the suitable d - and q -axis reference currents to control PMA-SynRM motors with high efficiency. This paper presents the maximum torque per ampere (MTPA) to minimize the copper losses of the system and utilizes the field weakening control to operate above the rated speed of the PMA-SynRM. The copper losses equation and electromagnetic torque are used to optimize the d - and q -axis current references. A small-scale 1 kW prototype PMA-SynRM was designed and manufactured to test and examine the proposed control in the laboratory. The proposed algorithm was digitally carried out using the MicroLab Box dSPACE. The simulation results show that the copper losses of the machine with the MTPA algorithm are lower than those without the MTPA algorithm. The PMA-SynRM operates above the base speed of ~ 70 % in the constant power region by mean of field weakening control.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.