Abstract

The design of a novel instantaneous frequency measurement module based on the interferometer phase-comparison method is proposed in this paper. Relative to heterodyne receiver, the advantage of instantaneous frequency measurement is its measurement speed. Firstly, the basic operating principle of interferometer phase-comparison method is given. And then the module is fabricated and measured. The proposed instantaneous frequency measurement module consists of amplitude limited amplified and filtered circuit, power divided circuit, phase shift network, AD and coding circuit, etc. The measurement results show that the sensitivity of this module is better than −75dBm, the frequency measurement accuracy is about 5MHz, the speed could reach about 0.1us. The total dynamic range is from −75dBm to +25dBm. The performance of the proposed module satisfies the requirement of the design, and the module has been used in some equipment. Finally, the frequency measurement error is analyzed. The frequency measurement error in some frequency points exceeds 8MHz in 85°C,because the LO power of I/Q phase detector decreases in higher temperature and cause the loss increasing. It can be solved by tuning the power of LO amplifier.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.