Abstract
Hard X-ray photoacoustic signal intensities of brass have been measured in the Cu K-edge region as functions of sample thickness d (from 10 µm to 300 µm) and modulation frequency f (from 5 Hz to 50 Hz). The photoacoustic signal intensities are proportional to d-1 for each modulation frequency. The X-ray photoacoustic signal varies as f-1.0 up to a sample thickness of 20 µm, whereas it varies as f-0.5 beyond the sample thickness of 20 µm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.